  1. Locate the air inlet cap, found on the far right side of the oven burner as shown in Figure 1. The oven burner can be found by removing the rectangular burner cover on the floor of the oven.
  2. The mounting screw on the far left side of the oven burner can be removed to allow easier access to the air inlet cap.
  3. Loosen but do not remove the screw on the oven burner’s air inlet cap. The location of the screw is indicated by the red arrow seen in Figure 1.
  4. Rotate the air inlet to align the cap with the engraved marking matching your gas type (NG / LPG). 
  5. Tighten screw on the burner’s air inlet cap.